Ensuring the quality and performance of NEB’s enzymes is of paramount importance, both to you, our customer, and to us. All of our restriction enzymes undergo stringent quality controls (below), and we are constantly testing their performance through our internal research programs. The result is a consistently superior restriction endonuclease that delivers on its promised performance and activity.
NEB extensively quality controls its popular lines of standard and high-fidelity (HF®) restriction enzymes. Each new lot is tested and must meet the specifications designated for the product. Quality controls for restriction enzymes, both standard and HF, include:
Restriction Enzyme Competitor Study: Nuclease Contamination
EcoRI, NotI, and BamHI from multiple suppliers were tested in reactions containing a fluorescent labeled single stranded, double stranded blunt, 3’overhang or 5’ overhang containing oligonucleotides. The percent degradation is determined by capillary electrophoresis and peak analysis. The resolution is at the single nucleotide level.