Typical LAMP Protocol (M0275)
Component | 25 µl Reaction | Final Conc |
10X ThermoPol Buffer | 2.5 µl | 1X (contains 2 mM MgSO4) |
MgSO4 (100 mM) | 1.5 µl | 6 mM (8 mM total) |
dNTP Mix (10 mM) | 3.5 µl | 1.4 mM each |
FIP/BIP Primers (25X) | 1 µl | 1.6 µM |
F3/B3 Primers (25X) | 1 µl | 0.2 µM |
LoopF/B Primers (25X) | 1 µl | 0.4 µM |
Bst DNA Polymerase, Large Fragment (8,000 U/ml) | 1 µl | 320 U/ml |
DNA Sample | variable | > 10 copies or more |
Nuclease-free Water | to 25 µl | |
Total Reaction Volume | 25 µl |
General Guidelines:
- A LAMP Primer Mix can be prepared with all 4 or 6 (with Loop) primers. A 25X Primer Mix should contain: 40 µM FIP, 40 µM BIP, 5 µM F3, 5 µM B3, 10 µM LoopF, 10 µM LoopB in TE or water.
- Reactions should be setup on ice. If room temperature setup is desired, use Bst 2.0 WarmStart® DNA Polymerase (NEB #M0538).
- If analyzing via agarose gel electrophoresis or other method requiring opening LAMP reaction vessels, setup secondary analysis area and equipment to avoid contamination.
- Running a no-template control is strongly recommended to ensure amplification specificity.
- If optimization is desired, try titrating Mg2+ (4–10 mM final) or Bst DNA Polymerase, Large Fragment (0.04–0.32 U/µl), or changing reaction temperature (50–68°C).