The Luna Probe One-Step RT-qPCR 4X Mix with UDG (No ROX) enables sensitive detection of target RNA sequences, with robust performance in multiplex applications of up to 5 targets.
The Luna Probe One-Step RT-qPCR 4X Mix with UDG (No ROX) is designed for real-time detection of target RNA sequences using hydrolysis probes. In a single tube, RNA is first converted to cDNA by a reverse transcriptase, then a DNA-dependent DNA polymerase amplifies the cDNA, enabling quantitation via real time or quantitative PCR (qPCR). Probe-based qPCR/RT-qPCR monitors an increase in fluorescence upon 5´ to 3´ exonuclease cleavage of a quenched, target-specific probe to measure DNA amplification at each cycle of a PCR. At a point where the fluorescence signal is confidently detected over the background fluorescence, a quantification cycle or Cq value can be determined. Cq values can be used to evaluate relative target abundance between two or more samples.
The Luna Probe One-Step RT-qPCR Mix with UDG (No ROX) is supplied at a 4X concentration and enables higher amounts of sample input, which is relevant for applications where RNA present in low abundance is of interest, such as pathogen detection. Performance in multiplexing applications has been optimized, with sensitive, linear detection achieved for up to 5 targets across a range of inputs. The mix consolidates the necessary components for one-step RT-qPCR into a single tube, including Luna WarmStart RT, Hot Start Taq DNA Polymerase, dNTPs, and Murine RNase Inhibitor in an optimized buffer. Combining Hot Start Taq DNA Polymerase with a novel, WarmStart-activated reverse transcriptase allows for dual control of enzyme activity via reversible, aptamer-based inhibition. This temperature-dependent activation helps to prevent undesirable non-specific priming and extension prior to thermocycling, providing added security for setting up reactions at room temperature. The engineered Luna WarmStart RT also possesses higher thermostability than many other RTs, allowing an optimal reaction temperature of 55°C. This formulation contains no reference dye and is compatible with any instrument that does not require ROX (if ROX normalization is needed, ROX can be added.)
The sensitivity of RT-qPCR makes it important to minimize DNA contamination wherever possible. The inclusion of dUTP and thermolabile UDG prevents carryover contamination, where unintended product of a previous amplification can serve as the substrate of a subsequent reaction. The thermolabile UDG is completely inactivated at temperatures above 50°C, thereby having no effect on qPCR performance.
The following reagents are supplied with this product:
NEB # | Component Name | Component # | Stored at (°C) | Amount | Concentration |
Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.
This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.Nucleic acid-based aptamers for use with thermophilic DNA polymerases and reverse transcriptases are licensed exclusively by New England Biolabs, Inc. from SomaLogic, Inc. New England Biolabs, Inc. gives the Buyer/User a non-exclusive license to use the Luna® Probe One-Step RT-qPCR 4X Mix with UDG (No ROX) product for Research Use Only (RUO). Commercial use of this product may require a license from New England Biolabs, Inc. For additional information or to inquire about commercial use, please contact busdev@neb.com.